Entered | By | Comment | View | |
3/17/1999 | Ken Giles | Gamma readings of 87.2uR on 15 march 1999 are from EPApersonal doing source checks | Station Info | Data Graph |
3/11/1999 | Ken Giles | Gamma reading on march 2,1999 of 111.uR and on march 9,1999 of 124.9uR were from source checks preformed by EPA personal doing routine maintance on the equipment. | Station Info | Data Graph |
11/3/1998 | Ken Giles | DATA WAS INTERRUPTED BETWEEN 1700-1930 HRS ZULU TIME F0R STA. MAINTANCE AND THE INSTALLATION OF A VOLTAGE REGULATOR. | Station Info | Data Graph |
8/18/1998 | Larry Sanders | The station was loaded with NEWNET version R35 software today at 18:50Z. This software provides improved accuracy for radiation measurements in the low range. The station was re-wired with a door sensor and new voltage divider for the radiation sensor. A new 12volt battery was installed. The PIC 300volt battery voltage was ok (288.4volts). The relative humidity sensor appears to be working correctly at the station, but data processing software for this sensor at Los Alamos is in error. Software engineers at Los Alamos are working on the problem. | Station Info | Data Graph |
3/23/1998 | Herb Maunu | Measurements displayed on Mar. 18 (julian day(077)) at 10:39 hrs (PST) and 10:54 hrs (PST)are QA check source measurements
for gamma detector operation and system performance. We are
evaluatin the humidity sensors and software programs to
correct the current problems with the unit. | Station Info | Data Graph |
3/16/1998 | Herb Maunu | High radiation measurements displayed on Tuesday March 11(day 070) were caused by a radioactive check source used for QA control. Humidity measurements showing 9999.9 indicates a problem and will be corrected. | Station Info | Data Graph |
3/5/1998 | Herb Maunu | Listed below are QA radioactive check source measurements for quality control on gamma data and system performance. epa/hkm
Mar. 04 11:39 hrs (PST) 41.4 uR/hr Mar. 04 11:54 hrs " 103.0 " | Station Info | Data Graph |
2/14/1998 | Herb Maunu | Measurements displayed on Feb. 11 09:09 hrs (PST) and 09:24 hrs (PST) showing 48.9 uR/hr and 113.0 uR/hr are valid numbers
of a QA radioactive check source. | Station Info | Data Graph |
2/14/1998 | Herb Maunu | QA radioactive check source measurements were performed on Feb. 5th 09:09 hrs and 09:24 hrs showing 118.8 uR/hr and
44.0 uR/hr. System operating normal. | Station Info | Data Graph |
1/30/1998 | Herb Maunu | QA radioactive check source measurements displayed on Jan. 22nd 12:39 hrs (63.3 uR/hr) and 12:54 hrs (46.1 uR/hr). Also at 13:27 hrs on Jan 27th a reading of 94.0 uR/hr was
corded. These measurements are valid for the check source.
All hours are recorded in Pacific Standard Time (PST). | Station Info | Data Graph |
|