3/17/1999 | Ken Giles | Gamma readings of 111.9uR on march 17, 1999 are from EPA personal doing source checks | Station Info | Data Graph |
3/11/1999 | Ken Giles | gamma readings on march 3,1999 of 87uR and on march 12, 1999 of 111.9uR were from source checks preformed by EPA personal doing routine maintance on the equipment. | Station Info | Data Graph |
8/28/1998 | Larry Sanders | The station was loaded with NEWNET version R35 software on 8/27/98 at 16:30Z. This software provides improved accuracy for radiation measurements in the low range. The station was re-wired with a door sensor and new voltage divider for the radiation sensor. The existing PIC battery was reading 305 volts, it was not replaced. A new 12volt battery was installed at the station. Currently, this station only has a radiation sensor. EPA will install meteorological sensors later. All meteorological inputs will remain shorted until the meteorological sensors are installed. | Station Info | Data Graph |